Unplanned Roof fall at 5 MN xc25. Fall occurred in intersection (4-way)slip plane that was supported with 72"" TR bolts and 11 ft. cable bolts. fell from roof. Fall dimensions 19'W x 30'L x 8'-10'H. Fall did not cause injury, impair ventilation, or entrap miners.