A non-injury roof fall occurred in the 1st Northeast Mains. The fall area was 20' by 20' by 6.5'. The area is supported by 48"" fully grouted bolts and 8' cable bolts. The travelway and ventilation were not affected. At this time the fall area will not be cleaned up. MSHA has investigated this fall.