While pre-shift to the section was in the process, the examiner found a roof fall in #3 entry on the front MBC. area was dangered off and a report was phoned outside of the discovery. Fall was aprox. 30 foot long 25 foot wide and 4 foot thick, fall was located in #3 entry of M butt