A roof fall occurred in the 5 West (MMU 005-0) continuous miner section at x-cut #11, #3 entry. The fall occurred near a flush face. The fall did not impede travel of persons or block an escpaeway. The fall measured aprox 18' wide x 10' long x 4'-5' high. The entire area was bolted with 5' bolts, mesh and mats.