# FALL OF ROOF OR BACK
> MSHA accident `220151700009` · 06/16/2015 · Midland Trail Energy LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Patriot Coal Corporation
- **Operator:** Midland Trail Energy LLC
- **Mine:** [4609297](https://api.ai-analytics.org/mine/4609297)
## Narrative

Unintentional roof fall was found in a return off our 2 Left Mining section.  The area where the fall occurred was bolted with 5 foot resin rods with draw rock pans as needed.  The fall occurred in the 45th c-cut on 1 left panel between the #6 & #7 entries.  Fall measure 20 feet wide at widest point and approx. 45 to 50 feet long and 5 foot high at the highest point.

---