A roof fall occurred in the 2nd 54 intake 3rd main east x-cut # 38 in the # 7 entry. The fall measured 20' x 20' x 6' and was caused by a hidden slip in the mine roof. The area was supported by 6' tension rebar bolts. The area was mined in April of 2008. There were no injuries, no equipment involved and ventilation was not affected.