A roof fall was found in entry 6 XC 70-71 west intakes. Area was mined in August of 2009 and had been supported with 4-6 ' resin pins. No injury or property loss occurred. There are no plans to clean up fall. Travelway is being rehabbed in entry 5 and will serve as the new primary escapeway. Fall was approximately 35' long X 20' wide X 8' high.