A unintentional roof fall was noticed by mine personnel. No injury or equipment damage occurred, with no interruption to the ventilation system. The roof fall measured approx 25 feet long and 17 feet wide, falling aaprox 2 feet above the anchorage point. The roof fall area was immediately dangered off and supplemental roof support set around the perimeter of the fall area.