An unplanned roof fall occurred at the 1585' mark in the 10 west tailgate entry number 2. The area had been mined in October 2012 and the fall occurred in a three way intersection. The area had previously been supported with 8' torque tension bolts in t-3 channel as the primary roof bolt with 12' cable bolts between the existing rolls of the primary bolts.