Unplanned roof fall at #61xc, #2 entry, ft. #9068 on #4L travel road. Fall occurred in intersection supported with 84"" tr bolts and 12'cable bolts. Fall dimensions 19' w x 19' L x 8'5"" h. Fall did not cause injury, impair ventilation, or entrap miners. Fall area developed 7-1-2015.