A roof fall occurred above the anchorage point at survey station 57+35on the mainline near the river portal. The fall was 12 feet long and 10 feet high and the width of the entry. The fall occurred due to the age of the area, weather it didn't involve any compliance issues it did impede travel, no equipment was involved no other 50.20 criteria applies.