A roof fall occurred out-by the 002 section on #11 belt between #208 and #209 x-cuts. The fall was 16 feet wide by 15 feet high by 45 feet long. The fall was reported because it was above anchorage. Approaches were re-bolted and cable bolted. Fall was cleaned up and a square set was installed according to our roof control plan.