# FALL OF ROOF OR BACK
> MSHA accident `220153270004` · 11/19/2015 · CONSOL of Kentucky Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** CONSOL of Kentucky Inc.
- **Mine:** [4609277](https://api.ai-analytics.org/mine/4609277)
## Narrative

Unintentional roof fall in unused entry. Fall location is 1st West mains inby spad 325. Fall measured approx. 16'W x 70'L x 5.5' high. Area was supported by 48"" resin bolt. No injuries, no equipment damaged & ventilation not interrupted. Fall was dangered off. No plan of moving the fall at this time. Time of the fall was approx. Fall was discovered later during day. Inactive mine.

---