## Operator
- **Controller:** Alan  Fritz; Larry  Lehtinen
- **Operator:** Mag Pellet
- **Mine:** [1202470](https://api.ai-analytics.org/mine/1202470)
## Narrative

On our Updraft Drying Fan failed and we had a fire in our Electrical Room (EER1). 45 minutes prior to this we know the current to the Fan went way up, speed went way down, power draw went way down, motor temps skyrocketed and the fan vibration decreased.

---