Roof fall was located in belt entry #3 of #4 belt line at break #60. Fall is approx 20'x30' and approx. 7-8' high. Cribs, Steel beams, jacks, and 10' cable bolts existed in the area prior to the fall. An action plan was submitted and includes plans for cleaning up and rehabilitation of the roof fall. The fall did not affect ventilation, miners, or equipment.