A roof fall was discovered on this date. The fall was located on the 2 Left panel at crosscut #22 in the #1 entry. The fall measured 70' by 18' and was 8' in thickness. The areas was previously supported with 6' torque tension bolts and 12' cable tension bolts. The return entry was rerouted and no persons were affected.