← MSHA accidents

HOISTING

220162160002 · 07/26/2016 · Cargill Salt

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
Cargill Inc
Operator
Cargill Salt
Mine
3000663

Narrative

While starting the test trip it was discovered that the # 2 hoist would not power up on line power OR generator power. Troubleshooting began and 4 hoist control fuses were found to be blown and 1 circuit breaker tripped. MSHA was called at 3:45pm and notified, at 5:33pm MSHA was notified that the hoist was back running.

Source

Authoritative
MSHA Open Government Data
Machine