A roof fall was discovered on this date. The fall was located on the 1-West Main at crosscut #12 in the #1 entry. The fall measured 20' by 25' and was 10' in thickness. The area was previously supported with 5' Hy-tech bolts and 12' cable bolts. Affected miners were removed from inby the location and the primary escapeway was re-routed.