# HOISTING
> MSHA accident `220171800010` · 06/25/2017 · Teck Washington Incorporated
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Teck Resources Limited
- **Operator:** Teck Washington Incorporated
- **Mine:** [4500366](https://api.ai-analytics.org/mine/4500366)
## Narrative

On June 25th, the hoist went down around 9:00pm.  The electrician on shift was not able to diagnose the problem so the hoist remained out of service for the remainder of the shift. The day shift electricians found that the hoist drive had tripped on over-voltage.  They adjusted settings to reduce the secondary voltage and brought the hoist back on line.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*