This area is part of the 7 day exam found by the examiner on their normal run. A roof fall was found which was 18x20x6. Travel way was blocked due to the fall, ventilation was not affected. The fall is due to normal weathering. This area was mined in March 2006. There were no injuries with this accident. This fall was located in the West B right side return at spad 37+64 H entry.