# ELECTRICAL
> MSHA accident `220172050033` · 07/15/2017 · The Ohio County Coal Company
## Details
- **Degree of injury:** DAYS AWAY FROM WORK ONLY
- **Classification:** ELECTRICAL
- **Accident type:** Flash burns (electric)
- **Occupation:** Longwall operator, Chock operator, Shear operator, Plow operator
- **Activity:** Electrical maintenance
- **Injury source:** ELECTRICAL APPARATUS,NEC
- **Nature of injury:** ELECT.ARC BURN-NOT CONTAC
- **Body part:** ABDOMEN/INTERNAL ORGANS
- **Days lost:** 30
- **Mine experience:** 7.02 years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** The Ohio County Coal Company
- **Mine:** [4601436](https://api.ai-analytics.org/mine/4601436)
## Narrative

Employee was unplugging de-energized charger plug from #69 cat scoop in the 4E section.  When the scoop plug arced causing burns to the employee's abdomen. Cause of accident was improperly wired breaker and loose plugs lead. Miner proficiency, skills or attitude was not an issue. PPE was not an issue.

---