An unintentional roof fall occurred in the 6 south area of the mine. Fall occurred in the #1 entry inby 57 xcut. Fall measured approx. 30ft long by 6ft high by 16ft wide. No injury or equipment damage. *It was determined that there were unusual adverse geological conditions in this area that caused the immediate roof to separate from material above the anchorage zone.