# FALL OF ROOF OR BACK
> MSHA accident `220173050008` · 10/23/2017 · Consol Pennsylvania Coal Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol Pennsylvania Coal Company LLC
- **Mine:** [3607230](https://api.ai-analytics.org/mine/3607230)
## Narrative

An unplanned roof fall occurred in the 6L section in the #2 entry just out by 33 x-cut.  The fall measured 15ft long by 6ft high by 10ft wide.  The opinion formed during the investigation was that the fall was caused by adverse geological condition, in the form of a cutter running up the left bolt line.  

---