Fall was discovered I-sub belt 9 crosscut. Fall was approx. 25ft long, 16ft wide, 42 inches high area was bolted with 8ft tension rebar and 16ft passive cable bolts area took weight and bolts broke causing fall. No ventilation, equipment or person affected.