An unintentional roof fall occurred in the E-29 longwall section in 1-2 cross cut at 18 wall. The fall was approximately 20' high x 16' wide x 36' long. The immediate roof consisted of laminated shale type material. Adverse geological conditions contributed to the failure. The fall was just inby the longwall face at the time the fall occurred.