During preshift exam a roof fall was discovered on the 2-East belt inby crosscut #29. The fall measured 16' by 16' and was 6-8' in thickness. No persons or ventilation was affected. The area was previously supported by 6' torque tension and 12' cable bolts. The area was cleaned up and re-supported.