A roof fall occurred in the E-29 LW section. The roof fall was located on the face and in the #3 belt entry. The fall was approximately 3' in front of the #2 & #3 shield tips and extended outby in the beltline to just inby the crusher. The immediate roof consisted of a laminated shale type material. It fell approximately 7' above the anchorage of the 8' bolts used in the area.