Roof Fall 5th South Panel entry 3 xc3. Maintenance EE found the fall around 1249am and reported to Management and they reported to the MSHA Immediate Accident number then went to get roof fall secured with timbers and dangered off and started investigation of fall. Fall was 18'x25'x10' hi bolted with 8' tr bolts, cable bolts, screened. Fall is secured.