← MSHA accidents

FALL OF ROOF OR BACK

220182420018 · 08/27/2018 · Consol Pennsylvania Coal Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol Pennsylvania Coal Company LLC
Mine
3610045

Narrative

An unintentional roof fall occurred in 3 North Mains in #10 entry from 9 wall to 11 wall. The fall measured approximately 12'-15' high by 16' wide and 450' long. There were no injuries as a result of this incident. The event occurred due to humidity in the area and a lateral shift which caused the 8' bolts to fail at there couplers.

Source

Authoritative
MSHA Open Government Data
Machine