An unplanned roof fall occurred at 4:35p.m. in the 1st East, panel #1 at spad 3+00, the roof fall was above anchorage, and continued into adjacent intersections. This is a worked-out area, no ventilation or escape way effected. Floor to roof support were installed and area dangered off. This roof fall will not be loaded out.