An unplanned roof fall was discovered in the 1st south sub-main intake out-by area at spad # 0+00. The area is not traveled except for examinations, no ventilation disruption experienced due to roof fall. Area previously supported, at time of mining, with 6' fully grouted bolts and supplemental supports consisting of 9' cable bolts.