An unplanned roof fall occurred above the anchor point at 2-32 3/4 crosscut to 2-34 crosscut. The fall was approximately 160 feet long by 16 feet wide and 8-10 feet high. There were no injuries involved with the incident. The fall does not affect ventilation but it does impede passage. The fall will be supported to gain access to travel the air course.