# ELECTRICAL
> MSHA accident `220183060008` · 11/01/2018 · Blackjewel L.L.C.
## Details
- **Degree of injury:** NO DYS AWY FRM WRK,NO RSTR ACT
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)
- **Activity:** Roof bolter, NEC
- **Injury source:** UNDERGRD MINING MACHINES
- **Nature of injury:** ELECT SHOCK,ELECTROCUTION
- **Body part:** BODY SYSTEMS
- **Days lost:** 0
- **Mine experience:** 0.02 years
## Operator
- **Controller:** Jeffery A  Hoops
- **Operator:** Blackjewel L.L.C.
- **Mine:** [1518361](https://api.ai-analytics.org/mine/1518361)
## Narrative

Employee had a hand on the pinner when there was a power surge due to a storm. The surge blew a lightning arrester and sent the energy through the mine and through the roof bolting machine shocking the employee. Employee had pain in chest and left arm. EE was taken to the hospital as a precautionary measure. EE was found to be in good health and released back to full duty.

---