CO sensor at 50 ton coal bin quit working and unknown to the operator. The operator ran the coal bin empty in order to perform repairs at the drive sprocket for the screw. There was no ventilation in the system and the agitator was not running causing material accumulation at the bottom of the bin. Co monitor failed giving a false reading pre and post explosion. No injuries.