A roof fall was discovered on this date. The fall was located on the B-2 Mains in the number 5 entry at crosscut 44. The fall measured 25' by 18' and was 7' in thickness. The area was previously supported with 5' Hy-Tech bolts and 12' super bolts. The fall did not affect persons or ventilation. The fall was cleaned up and the area re-supported.