B2-2 return area had a roof fall approx 350' long x 20' wide, unknown height. #2 entry from SS# 1688 to 100' inby SS# 1640. Roof Fall impeded travel in the return entries. Fall was reported at 8:35pm. Area was bolted with 6' fully grouted bolts. Area was laminated rock layers.