Unplanned roof fall discovered reportable at 27 block 6 North haulage. The outby brow fell of an overcast, approximately 15' long, 15' wide and 8' high. The fall was caused by gradual degradation above the anchorage zone from water and moisture infiltration in the presence of clay intrusions.