# FALL OF ROOF OR BACK
> MSHA accident `220192550005` · 09/02/2019 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

A roof fall occurred in the inactive bleeder between 2W and 3W in the #2 entry located at spad 18+47. The fall was approx. 30' in length, 17' wide and 6' in height. Area was bolted using 8' point anchor resin assisted bolts and 12' CC cable bolts. Area also utilized wire mesh and bacon straps. Cause of this fall was deterioration of roof due to weathering. 

---