# FALL OF ROOF OR BACK
> MSHA accident `220193080017` · 10/30/2019 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

A roof fall occurred in the #1entry of North Mains at 48 x-cut. The fall was approx.35' in length,18'wide and 9'high.Area was bolted 8'point anchor resin assisted bolts, supplemental support consisted of bacon straps, wire mesh. Cause of the fall was deterioration of roof due to weathering. 

---