# FIRE
> MSHA accident `220193180001` · 11/08/2019 · GCC Rio Grande Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FIRE
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** GCC SAB de CV
- **Operator:** GCC Rio Grande Inc
- **Mine:** [0504822](https://api.ai-analytics.org/mine/0504822)
## Narrative

RRT Fire. The slide gate on the TDF system was closed (Showing open in control room). This caused material to back up. Maintenance cleared the plug and opened the gate. The leftover RRT was left on the rotary feeder level. The material ignited from the heat and caused electrical damage.

---