A bore miner was parked in an area under roof support to replace a shear pin. The roof was checked visually and appeared to be in good condition. A 5""x10""x1-3"" thick piece of the roof, in front of the bore miner and inby roof bolts, separated, broke apart and fell. A piece of the material hinged, swung toward the miner, and hit EE.