A roof fall occurred in the #2 entry at 30 1/2 xc of 72 HG section. The fall was 10.5 feet long and 8 feet wide. the fall was just above the anchorage point of the 6' bolts. No one was injured. The area was re-bolted using 16' bolts and the fall was cleaned up.