Doing a liner change, installing wear plates on inside of tub of the K400 crusher, EE was in bottom of tub aligning wear plate. A jack was installed from cone head to the wear plate to get it ready for welding. Everything was in place and when they let it go, the jack gave out causing the plate to come down landing on EE's left hand, causing the injury.