# FALL OF ROOF OR BACK
> MSHA accident `220201600010` · 06/04/2020 · Wilson Creek Energy LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Quintana Capital Group GP Ltd
- **Operator:** Wilson Creek Energy LLC
- **Mine:** [3609893](https://api.ai-analytics.org/mine/3609893)
## Narrative

the 4 right area had a roof fall approx. 20' wide X 100' long X unknown Height. #4 entry 1 cross cut inby SS 3751 fall continued inby for 100'. Fall was reported at 2:08PM. Area was bolted with 4' fully grouted bolts. ""No bed separation or visible defects in the roof in this area. Cause of the roof fall is unknow."" 

---