# FALL OF ROOF OR BACK
> MSHA accident `220202160025` · 07/28/2020 · Prairie State Generating Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Prairie State Energy Campus Management Inc
- **Operator:** Prairie State Generating Company LLC
- **Mine:** [1103193](https://api.ai-analytics.org/mine/1103193)
## Narrative

A roof fall occurred in the second north off the second main east at S.S. 7+20. Between entry 9 and entry 10. The fall was 60 feet long x 18 feet wide x 8 feet high.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*