An unplanned roof fall was discovered in the 6 North Belt entry between the 21-22 block intersections. The fall is approximately 50' L x 12'W x 6-8'H. The fall was most likely caused by gradual deterioration of the mine roof. No problems with mining machines, PPE, training or compliance issues.