# HOISTING
> MSHA accident `220202720005` · 09/24/2020 · Sunrise Coal, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Hallador Energy Company
- **Operator:** Sunrise Coal, LLC
- **Mine:** [1202394](https://api.ai-analytics.org/mine/1202394)
## Narrative

During an inspection of the Emergency hoist it was discovered that the brake pad for the drum had pulled through the rivets and caused the pad to break in two.  This was the only braking system for the drum as there is no secondary system.  The hoist was immediately taken out of service and repairs started.  

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*