A roof fall occurred on 10/22/2020 during the night time & no miners were in the mine at that time. This occurred at Panel #3 W at cross cut 38 F3 & 38 G3 in an area that had been mined. The area has been barricaded & a formal geotechnical engineering study of this area is bein conducted. It appears the fall occurred below the anchor zone of the 42"" fgr bolts.