An unplanned roof fall was discovered in the Old 5 North Mains #1 Entry at 8 block. The fall is approximately 120' long x 10' high and 16' wide. The fall was most likely caused by gradual deterioration of the mine roof. No problems with mining machines, PPE, training or compliance issues. This fall also did not disturb any ventilation or escapeways.