# FALL OF ROOF OR BACK
> MSHA accident `220210770002` · 03/10/2021 · Westmoreland San Juan Mining LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Westmoreland Mining Holdings LLC
- **Operator:** Westmoreland San Juan Mining LLC
- **Mine:** [2902170](https://api.ai-analytics.org/mine/2902170)
## Narrative

The Mine examiner noticed a roof fall had occurred in an entry adjacent to the examiner's normal route. It is unknown when this fall occurred. Intersection in East Mains, Entry #1, at Crosscut 49 had fallen. The entire intersection fell in and is approximately 20 ft Wide and 19 Ft Long. It fell above the 6 ft resin bolts and cable trusses that had been installed. 

---